dead time type selection and configuration
DB2_FED_UPMETHOD | Update method for FED (falling edge delay) active register. 0: immediate, bit0: tez, bit1: tep, bit2: sync, bit3: freeze |
DB2_RED_UPMETHOD | Update method for RED (rising edge delay) active register. 0: immediate, bit0: tez, bit1: tep, bit2: sync, bit3: freeze |
DB2_DEB_MODE | S8 in documentation, dual-edge B mode, 0: fed/red take effect on different path separately, 1: fed/red take effect on B path, A out is in bypass or dulpB mode |
DB2_A_OUTSWAP | S6 in documentation |
DB2_B_OUTSWAP | S7 in documentation |
DB2_RED_INSEL | S4 in documentation |
DB2_FED_INSEL | S5 in documentation |
DB2_RED_OUTINVERT | S2 in documentation |
DB2_FED_OUTINVERT | S3 in documentation |
DB2_A_OUTBYPASS | S1 in documentation |
DB2_B_OUTBYPASS | S0 in documentation |
DB2_CLK_SEL | Dead time generator 2 clock selection. 0: PWM_clk, 1: PT_clk |